วันเสาร์ที่ 19 ตุลาคม พ.ศ. 2556

Limit Switch Omron รุ่น HL-5030

Product Description
Limit Switch Omron รุ่น HL-5030

5A 250VAC   / 3A 250 VAC

0.4A 125VDC

0.2A 250VDC

Shape / StructureGeneral-purpose Limit switches
service lifeGeneral type
Operating mechanismSnap action
ActuatorAdjustable roller lever
Frequency50/60 Hz
Switching mechanismSelf-reset mechanism
Contact configuration2-circuit double break type
Contact formSPST-NO / SPST-NC
LoadGeneral load
Ratings (AC): Non-Inductive loadRated voltage: 125 VAC, Resistive load: 5 A (NC) 5 A (NO), Lamp load: 1.5 A (NC) 0.7 A (NO)
Rated voltage: 250 VAC, Resistive load: 5 A (NC) 5 A (NO), Lamp load: 1 A (NC) 0.5 A (NO)
Ratings (AC): Inductive loadRated voltage: 125 VAC, Inductive load: 3 A (NC) 3 A (NO), Motor load: 2 A (NC) 1 A (NO)
Rated voltage: 250 VAC, Inductive load: 3 A (NC) 3 A (NO), Motor load: 1.5 A (NC) 0.8 A (NO)
Ratings (DC): Non-Inductive loadRated voltage: 12 VDC, Resistive load: 5 A (NC) 5 A (NO), Lamp load: 3 A (NC) 3 A (NO)
Rated voltage: 24 VDC, Resistive load: 5 A (NC) 5 A (NO), Lamp load: 3 A (NC) 3 A (NO)
Rated voltage: 125 VDC, Resistive load: 0.4 A (NC) 0.2 A (NO)
Rated voltage: 250 VDC, Resistive load: 0.4 A (NC) 0.2 A (NO)
Ratings (DC): Inductive loadRated voltage: 12 VDC, Inductive load: 4 A (NC) 4 A (NO), Motor load: 3 A (NC) 3 A (NO)
Rated voltage: 24 VDC, Inductive load: 4 A (NC) 4 A (NO), Motor load: 3 A (NC) 3 A (NO)
ExplanationThe above values indicate the steady-state current. Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current.
Inrush currentNC: 24 A
NO: 12 A
Earth terminalWith ground terminal
Ambient temperatureOperating: -5 to 65 CEL
(with no icing or condensation)
Ambient humidityOperating: 35 to 95%RH
(with no icing or condensation)
Permissible operating speed5 mm/s to 0.5 m/s
Permissible operating frequency (Mechanically)120 operations / 1 minute Max.
Permissible operating frequency (Electrically)30 operations / 1 minute Max.
Contact resistance25 mOhm Max. (Initial value)
(Measuring method is contact resistance meter.)
Insulation resistanceBetween each terminal of the same polarities: 100 MOhm Min.
Between live-metallic part and ground: 100 MOhm Min.
Between each terminal and non-live-metallic part: 100 MOhm Min.
(at 500 VDC Megger)
Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC
Between live-metallic part and ground: 1,500 VAC
Between each terminal and non-live-metallic part: 1,500 VAC
(50/60 Hz for 1 min)
Durability (Mechanically)10,000,000 operations Min. (No load)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Durability (Electrically)500,000 operations Min. (Resistive load 5 A at 125 VAC)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Vibration resistance (Malfunction)Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
Shock resistance (Destruction)1,000 m/s2
Shock resistance (Malfunction)Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2.
Degree of protectionIEC60529 (JEM): IP65
Applicable standard (TUV)Standard No.: EN60947-5-1
File number: B 07 08 39656 145
Applicable standard (CCC(CQC))Standard No.: GB14048.5
File number: 2003010303077624
Applicable standard (EC Directive (Low Voltage Directive) )2006/95/EC
Mounting specificationFront mounting (diagonal), Back mounting (diagonal)
WeightApprox. 680 g
Operating Force (OF)Standard value 7.35 N Max.
Release Force (RF)Standard value 0.98 N Min.
Pre-Travel (PT)Standard value 20 DEG Max.
Over-Travel (OT)Standard value 50 DEG Min.
Movement Differential (MD)Standard value 12 DEG Max.